Table 416: Level 1 Status Inquiry Test (#621) 4 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Electronic Power Feed Inquiry Test (#622)<br />

Electronic Power Feed Inquiry Test (#622)<br />

4 FAIL For the TN2198 only:<br />

Received a status of Level 1 Pending Activation, the NT1 has a loss of<br />

power indicating a problem with the NT1.<br />

1. For the NT1 follow the manufacturers recommended repair<br />

procedures.<br />

2. Enter <strong>test</strong> port location, <strong>and</strong> review the results of the Level 1<br />

Status Inquiry <strong>test</strong> to verify the repair. If the <strong>test</strong> is still failing,<br />

escalate the problem.<br />

PASS Level 1 is activated or the system has taken the port out of service.<br />

This <strong>test</strong> queries the BRI-LINE circuit pack for the status of the Electronic Power Feed (EPF)<br />

supplied to a BRI endpoint or an ASAI or <strong>Avaya</strong> adjunct. If the EPF is on <strong>and</strong> no overcurrent<br />

condition exists, this <strong>test</strong> passes. All other states are not normal <strong>and</strong> indicate a problem with the<br />

endpoint or adjunct, the wiring to the endpoint or adjunct, or the BRI-LINE circuit pack. This <strong>test</strong><br />

is not run on the TN2208 circuit pack or the TN2198 <strong>and</strong> will always return a pass for the<br />

TN2198. The TN2208 has no power feeds<br />

This <strong>test</strong> runs on BRI-PORT (ISDN-BRI Port).<br />

Table 417: Electronic Power Feed Inquiry Test (#622) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

4 of 4<br />

1005 ABORT This <strong>test</strong> is not valid for this port type. Ports on the TN2208 cot run this <strong>test</strong><br />

because this board does not have an electronic power feed. This <strong>error</strong> can<br />

be ignored.<br />

1 of 2<br />

Issue 5 May 2009 1407