Table 403: Expansion Interface Packet Interface Test (#589) 5 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Expansion Interface Packet Interface Test (#589)<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

ANY FAIL The transmitted data packet was not received correctly by the Packet<br />

Interface circuit pack. The failure may be in the EI under <strong>test</strong>, the DS1<br />

converter circuit packs, or the intervening Center Stage components.<br />

1. Test the Packet Interface circuit with <strong>test</strong> packet-interface<br />

CS where “C” is the IPSI’s carrier in a high- or critical-reliability<br />

system, <strong>and</strong> “S” is the slot number where the IPSI’s Packet Interface<br />

resides. If the Packet Interface circuit fails any <strong>test</strong>s, see PKT-INT<br />

(Packet Interface).<br />

2. If the EI under <strong>test</strong> resides in a high-reliability system’s PN,<br />

(2 PN-to-CSS fibers in an unduplicated PNC), run the short <strong>test</strong><br />

sequence on both of the PN’s EI boards, <strong>and</strong> follow procedures for<br />

Test #589.<br />

3. Enter display <strong>error</strong>s <strong>and</strong> resolve any PKT-BUS <strong>error</strong>s.<br />

4. Perform the Fiber link fault isolation in Chapter 4: General<br />

troubleshooting in Maintenance Procedures for <strong>Avaya</strong> Aura<br />

Communication Manager, Media Gateways <strong>and</strong> Servers<br />

(03-300432).<br />

PASS Although this <strong>test</strong> has passed, there may be related problems on other<br />

EIs used in connectivity to <strong>and</strong> from this EI. Software may have<br />

conducted <strong>test</strong>s on these other components <strong>and</strong> determined that this<br />

board was functioning properly <strong>and</strong> any problems were probably due to a<br />

problem with some other connectivity component. Check the <strong>error</strong> <strong>and</strong><br />

alarm logs for problems with other EI circuit packs <strong>and</strong> resolve these<br />

<strong>error</strong>s.<br />

1. Refer to other EI board <strong>test</strong>s if the link is not functioning correctly.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />

5 of 5<br />