SYS-PRNT (System Printer)<br />

3. Verify the availability of the external SYS-PRNT output device. Make sure that the output<br />

device is on-line <strong>and</strong> ready-for-service. Check the physical connectivity between the Data<br />

Module <strong>and</strong> the SYS-PRNT output device.<br />

4. Verify that there is at least one C-LAN port available. The System Printer Link cot be<br />

established without an available C-LAN port. For more information about C-LAN ports, see<br />

CLAN-BD (Control LAN Circuit Pack).<br />

5. If the problem is not found in the previous steps, check the C-LAN port for problems. For a<br />

description of C-LAN boards <strong>and</strong> connectivity, see CLAN-BD (Control LAN Circuit Pack).<br />

When restoring the System Printer link, execute <strong>test</strong>s on different MOs that comprise the<br />

System Printer link. It is recommended that you busyout the System Printer link before trying to<br />

restore the link. When the System Printer Link is busied out, every System Printer Link<br />

maintenance action is deactivated, <strong>and</strong> interference with <strong>test</strong>s of other MOs is prevented.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 250: SYS-PRNT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended<br />

Action<br />

0 0 Any Any Any <strong>test</strong> sp-link<br />

18 (a) 0 busyout sp-link WRN OFF release sp-link<br />

257 (b) 1, 3-6 Link Retry <strong>test</strong> (#215) MIN 1 WRN<br />

OFF <strong>test</strong> sp-link l<br />

513 (c) 0 MIN OFF <strong>test</strong> sp-link<br />

1. Minor alarms can be downgraded to Warning alarms based on the value used in set options.<br />

Notes:<br />

a. Error Type 18: the System Printer Link has been busied out.<br />

b. Error Type 257: a failure was encountered while attempting to set up the System Printer<br />

Link. This attempt could have been initiated by either Report Scheduler software or by link<br />

maintenance during automatic link retry or as a result of a Link Retry Test (#215) request.<br />

Issue 5 May 2009 931