Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

1. The values of these failure <strong>codes</strong> might be added together. For example, a value of 36 indicates that the<br />

ringer generator is inactive because of a short <strong>and</strong> that the ring generator has an internal fault.<br />

Reset Environmental Maintenance Test (#1545)<br />

This <strong>test</strong> resets the environmental maintenance on the TN2312BP IPSI board for CAB-MTCE<br />

(Media Gateway Maintenance).<br />

Table 550: Reset Environmental Maintenance Test (#1545) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description <strong>and</strong> recommendation<br />

1000 ABORT Internal software problem.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals 1 to 3 times.<br />

1982 ABORT The board being <strong>test</strong>ed is NOT a TN2312BP IPSI or later.<br />

1. Insert a TN2312BP IPSI circuit pack.<br />

1986 ABORT The TN2312BP IPSI failed to set emergency transfer to AUTO at<br />

initialization.<br />

1. Enter reset maintenance<br />

2. If the reset maintenance comm<strong>and</strong> aborts again, enter<br />

set emergency to see if emergency transfer can be activated or<br />

deactivated.<br />

3. If the reset maintenance comm<strong>and</strong> continues to abort, escalate the<br />

problem.<br />

2000 ABORT The response to a query was not received in the time allowed.<br />

1. Run reset maintenance<br />

2. Escalate the problem if the <strong>test</strong> continues to abort.<br />

2500 ABORT An internal operation failed. Possible unknown cabinet type.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals up to 3 times.<br />

2. Escalate the problem if the <strong>test</strong> continues to abort.<br />

1 FAIL The TN2312BP IPSI environmental maintenance initialization failed.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals 1up to 3 times.<br />

1708 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />