Table 197: M/T-PKT Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

M/T-PKT (Maintenance/Test Packet Bus Port)<br />

18 (c) 0 busyout port<br />

location<br />

WRN OFF release port location<br />

257 (d) Any MIN ON<br />

513 (e) Any Packet Bus Port<br />

Health Inquiry<br />

(#567)<br />

On/Off<br />

Board<br />

Recommended Action<br />

MIN ON <strong>test</strong> port location r 3<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its procedures.<br />

b. Error Type 1: hardware failure with the port circuitry that provides the packet bus<br />

maintenance functions. Replace the Maintenance/Test circuit pack if the alarm is not<br />

resolved by the <strong>test</strong> comm<strong>and</strong> above.<br />

c. Error Type 18: the port has been busied out by busyout port location. Release the<br />

port with release port location.<br />

d. Error Type 257: the Maintenance/Test packet bus port reconfigured the packet bus by<br />

swapping a bad lead to a spare. Note that this <strong>error</strong> is sent up whenever the Maintenance/<br />

Test packet bus port is initialized since the packet bus port reconfigures the packet bus to<br />

whatever state it determines the packet bus is in. This will occur if the circuit pack is<br />

inserted, if the system is restarted, or if the port is released from a busyout state. Therefore,<br />

it is normal for this <strong>error</strong> to be present in the <strong>error</strong> log.<br />

If the M/T-PKT reconfigures the packet bus 6 times within 15 minutes, a Minor alarm is<br />

raised indicating that either:<br />

● Packet bus maintenance functions are not operating correctly<br />

2 of 2<br />

● Many changes are taking place on the packet bus (insertions or removals of circuit<br />

packs)<br />

If the system has been in a stable state for more than 15 minutes, try the following<br />

procedure:<br />

1. Reset the Maintenance/Test circuit pack from a SAT session as follows:<br />

a. Enter busyout board location.<br />

b. Enter reset board location.<br />

c. Enter release board location.<br />

2. Wait 15 minutes.<br />

Issue 5 May 2009 685