Table 375: Expansion Interface Local Looparound Test (#240) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Expansion Interface Local Looparound (#240)<br />

1031 ABORT A query of the EI circuit pack aborted. The purpose of this query was to<br />

see if the EI circuit pack could detect the framing signal.<br />

1. If Test #238 aborted, follow the procedure associated with this<br />

abort code.<br />

2. If Test #238 did not abort, rerun Test #240 at 1-minute intervals up<br />

to 3 times.<br />

1032 ABORT The EI cot detect the framing signal <strong>and</strong> cot run the <strong>test</strong>.<br />

1. Refer to the <strong>error</strong>s for Expansion Interface Fiber Out-of-Frame<br />

Query Test (#238) to determine why the EI circuit pack is out of<br />

frame.<br />

1033 ABORT The EI circuit pack does not have a fiber link administered to it. There is<br />

not sufficient data to run <strong>test</strong>.<br />

1. Enter list fiber-link to verify that there is no fiber link<br />

administered to this circuit pack.<br />

2. If there is no fiber administered to this circuit pack, but there should<br />

be, enter add fiber-link to add the correct fiber.<br />

3. Retry the comm<strong>and</strong>.<br />

1394 ABORT The EI circuit pack is out of service <strong>and</strong> the <strong>test</strong> cot be run. This<br />

condition is due to a change in the EI circuit pack’s ability to<br />

communicate with the EI or SNI circuit pack on the other end of the fiber.<br />

1. Run Test #237, <strong>and</strong> check the Error Log for EXP-INTF Error Type<br />

1281. If Error Type 1281 is present or if Test #237 does not pass,<br />

see repair procedures for Expansion Interface Neighbor Query<br />

Test (#237)<br />

1395 ABORT This <strong>test</strong> cot be run on an EI circuit pack if it is part of the B-side PNC<br />

<strong>and</strong> duplicated PNC is not enabled.<br />

1. If this <strong>test</strong> needs to run on this EI circuit pack, enter<br />

change system-parameters duplication to enable PNC.<br />

2. Enter set pnc lock to prevent the system from doing a PNC<br />

interchange.<br />

3. Repeat this <strong>test</strong>.<br />

2 of 3<br />