Ring Generator Interchange Test (#1539)<br />

Ring Generator Interchange Test (#1539)<br />

The ring generator interchange <strong>test</strong> causes a temporary interchange <strong>and</strong> is only used if the<br />

G650 has redundant power supplies. This <strong>test</strong> sends a comm<strong>and</strong> to the primary power supply in<br />

slot 0 to turn off ringing voltage, the ring arbitration lead changes state, <strong>and</strong> the secondary<br />

power supply in slot 15 provides ringing voltage to the backplane. The ring detection circuit for<br />

the secondary power supply is checked to verify that the secondary power supply is providing<br />

ringing voltage.<br />

A comm<strong>and</strong> is sent to the primary power supply to apply ringing. The ring arbitration lead<br />

changes back to allow the primary power supply to provide ringing voltage. The ring voltage<br />

detection circuit on the primary power supply is checked to verify that the primary supply is<br />

applying ring voltage.<br />

The long <strong>test</strong> sequence causes a ring interchange. The short <strong>test</strong>, which is the default, does not<br />

cause a ring interchange.<br />

This <strong>test</strong> runs on PS-RGEN (Power Supply Ring Generator).<br />

Table 548: Ring Generator Interchange Test (#1539) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description <strong>and</strong> recommendation<br />

1000 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1035 ABORT The port network is not available.<br />

1. Verify that the port network is not available by using<br />

status port-network<br />

1990 ABORT Both power supplies in the carrier are turned off.<br />

2029 ABORT There is a problem communicating with the environmental maintenance<br />

firmware.<br />

1. Enter <strong>test</strong> maintenance nn to verify communication with the<br />

port network.<br />

2100 ABORT The system could not allocate resources.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals 1 to 3 times.<br />

2. If the <strong>test</strong> continues to abort escalate the problem.<br />

2319 ABORT The EPN is out of range.<br />