MEDPRO-C (Media Processor Control)<br />

j. Error Type 11yy1 <strong>and</strong> 11yy2: Health change. The state interchange (active/st<strong>and</strong>by) was<br />

caused by a fault condition in the Health parameter indicated by the code (yy). See<br />

Table 176 for a description of the Health Parameters monitored by the board <strong>and</strong> their<br />

values.<br />

Table 176: Health Parameter Index Codes for MEDPRO-C<br />

1yy Value Description<br />

100 Hardware problem<br />

101 Aggregator communication problem<br />

102 No DSPs<br />

103 Firmware resource failure<br />

104 Task monitor<br />

105 Critical Link (Eth or MPCL) fault<br />

119 Board out of service<br />

120 MPCL Relative Fault<br />

124 DSP 0<br />

125 DSP 1<br />

126 DSP 2<br />

127 DSP 3<br />

128 Software State of Health<br />

129 DoS Attack<br />

130 IP Conflict<br />

131 Network Configuration<br />