This <strong>test</strong> runs on FIBER-LK (Fiber Link).<br />

Table 444: Fiber Link Reset Test (#768)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Failure Audit (#777)<br />

Description / Recommendation<br />

Failure Audit (#777)<br />

1703 ABORT Both fiber endpoints are in the hardware path for INLs to their respective<br />

switch node carriers <strong>and</strong>, therefore, cot get a response from this <strong>test</strong>.<br />

1. Reset the individual fiber-link endpoints using reset board.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

PASS The reset of both fiber endpoints successfully completed.<br />

This <strong>test</strong> queries the SNI(s) on the fiber link for any existing failures <strong>and</strong> unacknowledged<br />

cleared failure messages. Each failure generates an <strong>error</strong> <strong>and</strong> alarm entry against SNI-BD,<br />

SNI-PEER, or FIBER-LK. An unacknowledged cleared failure message is a message sent by<br />

the SNI circuit pack to software indicating that a previous failure is now gone, <strong>and</strong> the SNI circuit<br />

pack did not receive a message from software indicating that the failure message was received<br />

by software.<br />

If no failures are detected by the SNI circuit pack, this <strong>test</strong> will pass.<br />

If this <strong>test</strong> reports failures, the results of <strong>test</strong> fiber-link will display FAIL with no FAIL<br />

code. The <strong>error</strong> log must then be displayed using display <strong>error</strong>s with category PNC to view<br />

SNI-BD <strong>and</strong> FIBER-LK <strong>error</strong>s. Enter display <strong>error</strong>s with category PNC-PEER to view<br />

SNI-PEER <strong>error</strong>s.<br />

This <strong>test</strong> is not run for EI-to-EI fiber links. For EI-to-SNI fiber links, this <strong>test</strong> is run on the SNI<br />

circuit pack endpoint of the fiber link. For SNI-to-SNI fiber links, this <strong>test</strong> is run on both SNI<br />

circuit pack endpoints of the fiber link.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● FIBER-LK (Fiber Link)<br />

● SNC-BD (Switch Node Clock Circuit Pack)<br />

● SNC-LINK (Switch Node Clock Link)<br />

● SNC-REF (Switch Node Clock Reference)<br />

Issue 5 May 2009 1489