g. Error Type 1281, 1290–1295: critical hardware or firmware <strong>error</strong>.<br />

If the switch detects: Then the switch:<br />

1 <strong>error</strong>, Resets circuit pack.<br />

3 <strong>error</strong>s in 15 minutes, Raises MINOR alarm.<br />

Error Type <strong>descriptions</strong> are as follows:<br />

1290 Global HDLC <strong>error</strong><br />

1291 Main RAM/ROM <strong>error</strong><br />

1292 CPU <strong>error</strong><br />

1293 Insane on-board processor<br />

1294 On-board translation RAM <strong>error</strong><br />

1295 (Aux 3) RSCL link down<br />

(Aux 0) RSCL keepalive failure<br />

1. Attempt to clear the alarm (reset board location).<br />

2. If the alarm persists, replace the circuit pack.<br />

h. Error Type 1537, 1796: a hyperactive VAL circuit pack has exceeded the <strong>error</strong> threshold<br />

<strong>and</strong> has been removed from service.<br />

1. Attempt to clear the alarm (reset board location).<br />

2. If the <strong>error</strong> recurs within 15 minutes, replace the circuit pack.<br />

i. Error Type 1794: packet bus transmit buffers have overflowed.<br />

1. Attempt to clear the alarm (reset board location).<br />

2. If the <strong>error</strong> recurs within 15 minutes, replace the circuit pack.<br />

j. Error Type 1798: unable to write translation RAM.<br />

1. Attempt to clear alarm (reset board location).<br />

2. If the alarm recurs within 15 minutes, replace the circuit pack.<br />

k. Error Type 2049: packet Interface <strong>test</strong> (#598) failed.<br />

1. Attempt to clear the alarm (<strong>test</strong> board location l r 3).<br />

2. If alarm does not clear, reset the circuit pack (reset board location).<br />

3. If circuit pack resets, execute Packet Interface <strong>test</strong> (#598) several times.<br />

4. If Packet Interface <strong>test</strong> (#598) continues to fail, replace the circuit pack.<br />

1044 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers