Figure 41: TN802 board assembly <strong>and</strong> cables (end view)<br />

Figure notes:<br />

ckdfmap3 KLC 040699<br />

1. Analogic board<br />

2. TMI (Texas Microsystems Inc.)<br />

board<br />

Replacing the Hard Disk<br />

MAPD-BD (MAPD Interface Circuit Pack)<br />

3. SIMMs (memory) 1<br />

4. SCSA (Signal Computing System Architecture)<br />

ribbon cable<br />

1. If the board is seated <strong>and</strong> you hear fast beeping, it means that one of the small boards containing the<br />

memory chips is dislodged. Secure the memory board firmly in the receptacle <strong>and</strong> reseat the circuit pack.<br />

The TN802 hard drive (Note 5 in Figure 40: TN802 board assembly <strong>and</strong> cables (side view)) can<br />

be replaced in the field.<br />

Table 170: Replacing the TN802 hard drive 1 of 2<br />

Step Description Comments<br />

1. Shut down Windows<br />

2000.<br />

1<br />

2<br />

3<br />

Shut down Windows 2000 by either method described in<br />

Shutting Down NT on the TN802.<br />

2. Remove the circuit pack. Unlatch the circuit pack, <strong>and</strong> remove it from the carrier.<br />

3. Remove the hard drive. Remove the 2 screws, <strong>and</strong> lift the hard drive out of its<br />

mounting bracket.<br />

4. Replace the hard drive. Position the new hard drive in the mounting bracket, <strong>and</strong><br />

replace the 2 screws (Step 3).<br />

4<br />

1 of 2<br />

Issue 5 May 2009 597