Expansion Interface Lightwave Transceiver Looparound Test (#242)<br />

Table 377: Expansion Interface Lightwave Transceiver Looparound Test (#242) 2 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1033 ABORT The <strong>test</strong> cot run because the EI circuit pack does not have a fiber link<br />

administered to it <strong>and</strong> there is not sufficient data to run the <strong>test</strong>.<br />

1. Enter list fiber-link to verify that there is no fiber link<br />

administered to this circuit pack.<br />

2. If there is no fiber administered to this circuit pack (but should be),<br />

add the correct fiber using add fiber-link.<br />

3. Retry the comm<strong>and</strong>.<br />

1139 ABORT The packet bus in the PN where this EI board resides has a major alarm<br />

against it. This <strong>test</strong> needs to use the alarmed PN’s packet bus.<br />

1. Enter display alarms <strong>and</strong> display <strong>error</strong>s <strong>and</strong> resolve any<br />

PKT-BUS alarms.<br />

2. Retry the comm<strong>and</strong>.<br />

1141 ABORT The Packet Interface circuit pack is out of service.<br />

1. See PKT-INT (Packet Interface).<br />

1144 ABORT The PN’s packet bus has a major alarm against it. This <strong>test</strong> needs to use<br />

the alarmed PN’s packet bus.<br />

1. Enter display alarms <strong>and</strong> display <strong>error</strong>s <strong>and</strong> resolve any<br />

PKT-BUS alarms.<br />

2. Retry the comm<strong>and</strong>.<br />

1394 ABORT The EI board is out of service <strong>and</strong> the <strong>test</strong> cot be run. This condition is<br />

due to a change in the EI board’s ability to communicate with the EI or<br />

SNI circuit pack on the other end of the fiber.<br />

1. Run Test #237 <strong>and</strong> check the Error Log for EXP-INTF Error Type<br />

1281. If Error Type 1281 is present or if Test #237 does not pass,<br />

see repair procedures for Expansion Interface Neighbor Query Test<br />

(#237).<br />