XXX-BD (Common Port Circuit Pack/Media Module)<br />

XXX-BD (Common Port Circuit Pack/Media Module)<br />

MO Name<br />

in Log<br />

XXX-BD 1<br />

Common Port Circuit Pack maintenance is a set of common <strong>test</strong>s used by many circuit packs<br />

<strong>and</strong> media modules. The common portion of these circuit packs/media modules is the generic<br />

hardware that interfaces with the TDM bus. The XXX-BD designation is also used on SAT<br />

displays when reset board is entered with an empty circuit pack or media module slot, or<br />

with a circuit pack or media module type that is in conflict with the actual board type<br />

administered for that slot.<br />

When any of the Common Port circuit packs or media modules are physically removed from the<br />

backplane, no alarm will be logged for approximately 11 minutes. In the case of the following,<br />

approximately 21 minutes will elapse before an alarm is logged:<br />

● TN754 Digital Line<br />

● TN758 Pooled Modem<br />

Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

MAJ<br />

MIN<br />

WRN<br />

● TN566 EMBEDDED AUDIX<br />

● TN2224 Digital Line Board<br />

● MM712 Digital Line Media Module<br />

● MM717 Digital Line Media Module<br />

● MM720 BRI Media Module<br />

● MM722 BRI Media Module<br />

● MM312 Digital Line Media Module<br />

● IMM-DCP Integrated Digital Line Board<br />

● VMM-2BRI Integrated BRI Media Module<br />

<strong>test</strong> board location Common Port Circuit Pack/<br />

Media Module maintenance<br />

1. Refer to the appropriate circuit pack or media module documentation for the correct MO name<br />

displayed in this field.<br />

● TIM521 Juniper BRI Media Module<br />

When a circuit pack or media module that has been removed is alarmed, the alarm type is minor<br />

<strong>and</strong> is classified as an on-board alarm. The time delay permits maintenance activity to be<br />

performed without triggering an additional alarm.<br />

Issue 5 May 2009 1065