Table 289: Local Loop Test (#13) 9 of 9<br />

Error<br />

Code<br />

Test<br />

Result<br />

Digital Station Lamp Update (#16)<br />

Digital Station Lamp Update (#16)<br />

PASS The Local Loop <strong>test</strong> passed. Every chel is transmitting properly.<br />

1. To ensure that this is not an intermittent problem, repeat this <strong>test</strong><br />

up to 10 times <strong>and</strong> see if it continues to pass.<br />

2. If the problem still exists, examine the connections, station, <strong>and</strong><br />

wiring.<br />

This <strong>test</strong> lights all lamps on the terminal as specified. The lamp updates run only if the station is<br />

in-service. The lamp updates are blocked from taking place if the station is not in the in-service<br />

state. This <strong>test</strong> does not affect the status of the Message Waiting lamp.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● DIG-IP-S (Digital IP Station)<br />

● DIG-LINE (Digital Line)<br />

Description / Recommendation<br />

● E-DIG-ST (Emulated Digital Line)<br />

● RC-BD (Radio Controller Board)<br />

Table 290: Digital Station Lamp Update Test (#16) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

9 of 9<br />

1 ABORT This port may have been busied out by a system technician.<br />

1. Look in the Error Log for Error Type 18 (port busied out) for this<br />

port. If this Error Type is present, release the port using the<br />

comm<strong>and</strong> release station extension <strong>and</strong> run the <strong>test</strong> again.<br />

2. Make sure the terminal is connected.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />