DID Trunk Testing<br />

The system uses technician-invoked <strong>test</strong>s of on-board circuitry to diagnose the health of the<br />

trunk. These are described in the following sections. Additionally, inline <strong>test</strong>ing which can<br />

generate <strong>error</strong>s, is performed while a call is in progress. See the Error Log table for a<br />

description of these <strong>error</strong>s. These <strong>error</strong>s may be reproduced by placing a call on the trunk <strong>and</strong><br />

checking the <strong>error</strong> log.<br />

Problems detected during signaling may be caused by off-board faults in the CO switch or<br />

connections for which a Warning alarm is raised.<br />

Before a maintenance <strong>test</strong> can be run on a port, the port must be idle. If an incoming call seizes<br />

a port that is being <strong>test</strong>ed, the <strong>test</strong> will abort <strong>and</strong> the incoming call will proceed.<br />

Ports Out-of-Service without Errors or Alarms<br />

A common trouble on DID trunks that produces no <strong>error</strong>s or alarms occurs when the CO busies<br />

out (disconnects) the port. This situation occurs when the CO thinks there are problems with the<br />

DID port. In this case, no incoming calls will be possible through this port. This may result in<br />

complaints from outside callers trying unsuccessfully to call in. This problem can be diagnosed<br />

by listing measurements on lightly used trunks. If a particular port is detected as idle, a call to<br />

the CO will be necessary to get the connection back in service.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 82: DID-TRK Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated<br />

Test<br />

Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> port location<br />

1 (b) Any WRN OFF<br />

1 (c) 57476 WRN OFF<br />

1 (d) 57477 WRN OFF<br />

1 (e) 57483 WRN OFF<br />

15 (f) Any Port Audit <strong>and</strong><br />

Update (#36)<br />

310 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />