SYNC (Port Network Synchronization)<br />

g. This <strong>error</strong> indicates excessive switching of system synchronization references has<br />

occurred. When this <strong>error</strong> occurs, synchronization is disabled <strong>and</strong> the Tone-Clock circuit<br />

pack (in the master port network) becomes the synchronization reference for the system.<br />

Execute the following steps to resolve this <strong>error</strong>:<br />

1. Check for timing loops, <strong>and</strong> resolve any loops that exist.<br />

2. Test the active Tone-Clock circuit pack in the master port network using <strong>test</strong><br />

tone-clock location long.<br />

Check the Error Log for TDM-CLK <strong>error</strong>s, <strong>and</strong> verify that TDM bus Clock Circuit Status<br />

Inquiry <strong>test</strong> (#148) passes.<br />

If Test #148 fails with Error Code 2–32, see TDM-CLK (TDM Bus Clock) to resolve the<br />

problem. If not, continue with the following.<br />

3. For duplicated Tone-Clock circuit packs in the master port network, enter set<br />

tone-clock location to switch the Tone-Clocks.<br />

For unduplicated Tone-Clock circuit packs in the master port network of a Stratum-4<br />

(not Stratum-3) system, replace the primary <strong>and</strong> secondary (if assigned) DS1 Interface<br />

circuit packs.<br />

4. Investigate any other SYNC or STRAT-3 <strong>error</strong>s.<br />

S8700-series Fiber-PNC<br />

h. This <strong>error</strong> indicates that the Expansion Interface circuit packs are experiencing timing slips.<br />

This <strong>error</strong> increases the bit <strong>error</strong> rates for data transmission between port networks. The<br />

Expansion Interface circuit packs with timing slips have EXP-INTF <strong>error</strong> 2305.<br />

1. Check the LEDs on the active Tone-Clock circuit packs in the system <strong>and</strong> verify that<br />

the system is properly synchronized.<br />

2. Verify that all the TDM/LAN Bus cables on the backplane are marked WP-91716. Also<br />

for a Multi-Carrier Cabinet (MCC), check that the bus terminator type is a ZAHF4 TDM/<br />

LAN.<br />

For a Single Carrier Cabinet verify that the bus terminator type is a AHF110 TDM/LAN.<br />

3. Check for timing loops, <strong>and</strong> resolve any loops that exist.<br />

4. Check the Error Log for any active as well as resolved Expansion Interface circuit pack<br />

<strong>error</strong>s <strong>and</strong> see EXP-INTF (Expansion Interface Circuit Pack) to resolve any <strong>error</strong>s<br />

found.<br />

5. Duplicated Tone-Clock circuit packs in the slave port networks:<br />

● Interchange Tone-Clock circuit packs in the slave port networks where EXP-INTF<br />

<strong>error</strong> 2305 also occurs using set tone-clock location. The <strong>error</strong> count for<br />

this <strong>error</strong> should start to decrement once the problem is solved. If the count does<br />

not decrease in 15 minutes, the problem still exists.<br />

Issue 5 May 2009 919