Packet Interface Read <strong>and</strong> Clear Counters (#887)<br />

Packet Interface Read <strong>and</strong> Clear Counters (#887)<br />

This <strong>test</strong> sends comm<strong>and</strong>s to read Packet Interface <strong>error</strong> counters located on the IPSI circuit<br />

pack. It also verifies the message interface between the server <strong>and</strong> the Packet Interface.<br />

This <strong>test</strong> checks different Packet Interface counters S8700-series Fiber-PNC: depending on<br />

whether the Packet Interface module is on the active or st<strong>and</strong>by IPSI.<br />

Running this <strong>test</strong> on the active IPSI circuit pack’s Packet Interface module reads <strong>and</strong> clears the<br />

Parity Error counter <strong>and</strong> FIFO Overflow counter. S8700-series Fiber-PNC: Those counters are not<br />

used when a Packet Interface module is in st<strong>and</strong>by mode.<br />

S8700-series Fiber-PNC: Running this <strong>test</strong> on the st<strong>and</strong>by IPSI circuit pack’s Packet Interface<br />

module, reads but does not clear a Translation RAM counter. The Translation RAM counter is<br />

not cleared since the number of bad translation RAM locations indicates bad locations that cot<br />

be used.<br />

For an active Packet Interface module, information about the number of bad Translation<br />

locations is sent to maintenance software as an inline <strong>error</strong> from the IPSI circuit pack, so it is not<br />

necessary to read a counter location.<br />

This <strong>test</strong> runs on PKT-INT (Packet Interface).<br />

Table 461: Packet Interface Read <strong>and</strong> Clear Counters Test (#887) 1 of 4<br />

Error<br />

Code<br />

1006<br />

1137<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT The IPSI circuit pack’s Packet Interface module is out of service.<br />

1. Enter reset packet-interface location to reset the<br />

Packet Interface. See Packet Interface Reset Test (#889).<br />

1335 ABORT Internal IPSI <strong>error</strong>. The <strong>test</strong> is on st<strong>and</strong>by IPSI’s Packet Interface<br />

module, so this <strong>test</strong> is not allowed to run.<br />

1. Enter set ipserver-interface location to make the<br />

st<strong>and</strong>by Packet Interface active.<br />

2. Rerun the <strong>test</strong>.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong>.<br />

1 of 4<br />