Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Test data patterns are transmitted from a Maintenance/Test board’s digital port over network<br />

time slot A through the digital port on the conversion resource, looped around through the<br />

analog port via time slot C back to the Maintenance/Test board’s digital port circuit via time slot<br />

B where the patterns are checked for accuracy. Finally, the <strong>test</strong> forces a disconnect by breaking<br />

the connection between the Maintenance/Test board’s digital port <strong>and</strong> the Modem Pool port<br />

(time slot A) <strong>and</strong> verifying that the Maintenance/Test board’s digital port <strong>and</strong> Modem Pool port<br />

go on-hook within the proper time. This <strong>test</strong> attempts to allocate a Maintenance/Test board’s<br />

digital port, Modem Pool port, <strong>and</strong> other internal resources. If any of these allocation attempts<br />

fail, the <strong>test</strong> cot be completed, <strong>and</strong> a specific abort <strong>error</strong> is reported.<br />

This <strong>test</strong> runs on MODEM-PT (Modem Pool Port).<br />

Table 321: Modem Pool Conversion Resource Looparound Test (#98) 1 of 5<br />

Error<br />

Code<br />

1000<br />

1180<br />

1181<br />

1182<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT System resources needed to complete the <strong>test</strong> could not be allocated for<br />

the digital section of the Modem Pool conversion resource. Ordinarily,<br />

this means the conversion resource or other hardware used during the<br />

<strong>test</strong> was in use.<br />

1. Wait 1 minute <strong>and</strong> attempt the <strong>test</strong> again.<br />

2. If the conversion resource is in use, <strong>and</strong> it is absolutely necessary<br />

to <strong>test</strong> it, the call will have to be dropped by entering busyout<br />

port location against the conversion resource.<br />

3. Run the <strong>test</strong> again. If the <strong>test</strong> passes, release the port with<br />

release port location<br />

4. If the same <strong>error</strong> occurs while the conversion resource is idle,<br />

busyout both Modem Pool conversion resources on the TN758<br />

Pooled Modem circuit pack containing the conversion resource<br />

under <strong>test</strong>. Rerun the <strong>test</strong>.<br />

5. If the <strong>test</strong> continues to abort, replace the Pooled Modem circuit<br />

pack <strong>and</strong> re<strong>test</strong>.<br />

6. If the <strong>test</strong> continues to abort with this <strong>error</strong> code after replacement,<br />

escalate the problem.<br />

ABORT No time-slots available to connect digital ports for the <strong>test</strong>.<br />

Internal system <strong>error</strong>. Failed to connect the digital ports with time-slots.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1196 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />