Communication Manager Maintenance Object Repair Procedures<br />

ATM-SYNC (ATM Synchronization)<br />

S8700-series Fiber-PNC<br />

This section discusses intra-switch synchronization maintenance <strong>and</strong> the hardware <strong>and</strong><br />

software components that provide a common reference frequency for reliable digital<br />

communications among the system, the ATM switch, <strong>and</strong> other PBXs, Central Offices (COs) or<br />

customer-premises equipment (CPE). Circuit packs involved in synchronization include:<br />

Note: TN768<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

ATM-SYNC MIN display <strong>error</strong>s ATM Synchronization<br />

Note:<br />

or TN780 Tone-Clock circuit packs are not compatible with ATM EIs.<br />

● TN2312 IPSI circuit pack’s Tone-Clock circuit<br />

● TN2182 Tone-Clock<br />

● TN722, TN464, <strong>and</strong> TN767 DS1 Interfaces (all suffixes)<br />

● TN2305/6 ATM Expansion Interface (multimode fiber)<br />

Synchronization is achieved between the S8700-series Server IPSI <strong>and</strong> the port networks<br />

(PNs) through the ATM port-network connectivity (ATM PNC) between the networks. Depending<br />

on the network’s synchronization plan <strong>and</strong> the status of synchronization sources, the system<br />

timing reference may be:<br />

● The clock circuit pack on the ATM switch<br />

● A DS1 or UDS1 interface circuit pack-tapped T1 input signal connected to the ATM switch<br />

clock circuit<br />

● An OC-3 interface circuit pack on the ATM switch<br />

Stratum 4 synchronization extracts timing information directly from<br />

● A DS1 or UDS1 reference<br />

● An OC3 reference<br />

WRN <strong>test</strong> synchronization<br />

● The ATM switch clock<br />

For further information about synchronization including network synchronization, refer to<br />

DEFINITY® Communications System Network <strong>and</strong> Data Connectivity, 555-025-201.<br />