Table 369: Neon Test (#220) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

140AY Chel Sanity Inquiry Test (#222)<br />

140AY Chel Sanity Inquiry Test (#222)<br />

FAIL The <strong>test</strong> failed because no neon current was detected.<br />

1. Determine if there is a TN755 or TN752 power unit circuit pack<br />

installed in the same carrier as the analog line circuit pack that<br />

failed the <strong>test</strong>. Look for the failure of <strong>test</strong> 220 on other analog<br />

circuit packs in the carrier. If <strong>test</strong> 220 fails on the other circuit<br />

packs, replace the TN755 or TN752 power unit circuit pack.<br />

2. Retry the comm<strong>and</strong> again.<br />

3. If the <strong>test</strong> continues to fail, replace the circuit pack.<br />

PASS Neon current is detected.<br />

Any NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />

This <strong>test</strong> queries the Angel to determine the status for a particular chel. If a chel is insane,<br />

ouncements cot be played back on that chel. This <strong>test</strong> runs on This <strong>test</strong> runs on -PT<br />

(Announcement Port).<br />

Table 370: 140AY Chel Sanity Inquiry Test (#222) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description/ Recommendation<br />

3 of 3<br />

ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals a maximum of 5 times.<br />

1 of 2<br />