Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

If there are any M/T-DIG <strong>error</strong>s in the Error Log, see M/T-BD (Maintenance/Test Circuit Pack)<br />

<strong>and</strong> clear them first.<br />

This <strong>test</strong> will pass regardless of any customer equipment that may be connected to the port, as<br />

long as the equipment is not using the port.<br />

This <strong>test</strong> runs on DAT-LINE (Data Line Port).<br />

Table 358: Digital Looparound Test (#171) 1 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run <strong>test</strong> are not available. The port may be<br />

in use on a valid call. Enter status data-module to determine when<br />

the port is available for <strong>test</strong>ing.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005<br />

1007<br />

ABORT Data Chel 3 is not administered. This port is required to run this <strong>test</strong>.<br />

1. Verify that data chel 3 is not administered with<br />

list data-module.<br />

2. Administer data chel 3 with add data-module, <strong>and</strong> run this <strong>test</strong><br />

again.<br />

1016 ABORT Data Chel 3 is busy. The port may be in use on a valid call. Enter status<br />

data-module to determine when the port is available for <strong>test</strong>ing.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals a maximum of 5 times.<br />

1020 ABORT An existing Error Type #769 on this port prevented the <strong>test</strong> from running.<br />

1. Follow the procedure described in the Error Log Table for Error Type<br />

#769 for this maintenance object.<br />

1042 ABORT The port under <strong>test</strong> is a TTI port <strong>and</strong> has only default translations with no<br />

assigned extension. The <strong>test</strong> requires an assigned extension associated<br />

with the port being <strong>test</strong>ed.<br />

1. If there is a need to run the <strong>test</strong> on this particular port, verify that the<br />

port is fully translated <strong>and</strong> has an assigned extension.<br />

1276 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />