19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

ASAI Link Status Test (#1365)<br />

This <strong>test</strong>s queries the system for the state of the TCP Tunnel Connection <strong>and</strong> the ASAI TCP/IP<br />

link. If both the TCP Tunnel Connection <strong>and</strong> the ASAI TCP/IP Link are in the "established" state,<br />

the <strong>test</strong> passes. The <strong>test</strong> fails otherwise. This <strong>test</strong> is run on ADJ-IP (ASAI Adjunct TCP/IP Link).<br />

Table 516: ASAI Link Status Test (#1365)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2500 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, escalate the problem.<br />

1 FAIL The ASAI Adjunct TCP/IP Link is down. The TCP Tunnel Connection is<br />

established but the ASAI TCP/IP Link is not established.<br />

1. Use the ping comm<strong>and</strong> with the IP address for the Remote Node<br />

as specified on the ip-services form.<br />

2. If no response is received, check the entry for the local node on the<br />

ip-services form. If the entry is clanX, where X is the board number,<br />

refer to the maintenance procedures for CLAN-BD (Control LAN<br />

Circuit Pack) to clear the problem.<br />

3. If the <strong>test</strong> continues to fail, escalate the problem.<br />

4 FAIL The ASAI Adjunct Link is down. The ASAI Adjunct Link is established but<br />

the TCP Tunnel Connection is not established.<br />

1. Check the entry for the local node on the ip-services form. If the<br />

entry is clanX, where X is the board number, refer to the<br />

maintenance procedures for CLAN-BD (Control LAN Circuit Pack) to<br />

clear the problem.<br />

2. If the <strong>test</strong> continues to fail, escalate the problem.<br />

PASS The ASAI Adjunct TCP/IP Link is up. The ASAI TCP/IP Link <strong>and</strong> the TCP<br />

Tunnel Connection are both "established".<br />

1646 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!