Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Sanity H<strong>and</strong>shake Test (#106)<br />

This <strong>test</strong> checks the ability of a PN’s Maintenance circuit pack’s to respond to queries. A<br />

message is sent to the PN’s Maintenance circuit pack. The <strong>test</strong> passes if a valid cabinet type is<br />

returned. This <strong>test</strong> runs on MAINT (PN Maintenance Circuit Pack).<br />

Table 323: Sanity H<strong>and</strong>shake Test (#106) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required for this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to query was not received in the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2033 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2046 ABORT The PN’s Maintenance circuit pack reported an invalid cabinet type,<br />

which will prevent all PN environment maintenance from running.<br />

1. Retry the comm<strong>and</strong>.<br />

2. If the <strong>test</strong> continues to abort with 2046, either the PN’s<br />

Maintenance circuit pack is defective or the PN cabinet’s wiring<br />

is defective. First, replace the Maintenance circuit pack, then<br />

re<strong>test</strong>.<br />

3. If the <strong>test</strong> continues to abort with 2046, the PN cabinet’s wiring<br />

is defective in the A carrier. The PN’s Maintenance circuit pack<br />

cot read the backplane pins to determine the cabinet type.<br />

10601 ABORT Test disabled via software patch.<br />

1202 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />