Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 300: Looparound <strong>and</strong> Conference Test (#47) 4 of 5<br />

Error<br />

Code<br />

7<br />

13<br />

14<br />

15<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL A <strong>test</strong> failed.<br />

● Error Code 7 - The conference <strong>test</strong> or the noise <strong>test</strong> failed.<br />

● Error Code 13 - The reflective looparound <strong>test</strong> with gain set to<br />

low <strong>and</strong> 600-ohm balance failed.<br />

● Error Code 14 - The reflective looparound <strong>test</strong> with gain set to<br />

high, using RC, balance failed.<br />

● Error Code 15 - The nonreflective looparound <strong>test</strong> failed.<br />

1. Disconnect the terminal equipment from the circuit pack at the<br />

cross-connect <strong>and</strong> run the <strong>test</strong> again.<br />

2. If the <strong>test</strong> fails again, replace the circuit pack <strong>and</strong> reconnect the<br />

terminal equipment. If the <strong>test</strong> passes the second time, this means<br />

the <strong>test</strong> results were affected by the terminal equipment connected<br />

to the port. In this case, ignore the results of this <strong>test</strong> if every other<br />

<strong>test</strong> passes or aborts <strong>and</strong> the station is operating properly. Failure<br />

of <strong>test</strong> 47 does not cause an alarm. If there are failures of other<br />

<strong>test</strong>s, investigate those <strong>error</strong>s. Investigate user-reported troubles<br />

with this port by using other port <strong>test</strong>s, by examining station wiring,<br />

<strong>and</strong> by examining the station to ensure that it is correctly translated<br />

as off-premises or on-premises.<br />

If the Looparound <strong>and</strong> Conference circuit <strong>test</strong> fails for every port on a<br />

circuit pack, a -5 Volt power problem is indicated. If a TN736 or TN752<br />

power unit circuit pack is present, either the 631DB AC power unit or the<br />

676B DC power unit may be defective. (The 631DB power unit is used in<br />

a medium cabinet powered by an AC source. The 645B power unit is<br />

used in a medium cabinet powered by a DC power source.) The system<br />

may contain a TN736 or TN752 power unit circuit pack or a 631DB AC<br />

power unit, but not both types of power units. To investigate problems<br />

with the power unit, see RMC-ENV (Power/Fan Sensors) or CARR-POW<br />

(Carrier Power Supply). If a red LED is lit on TN736 or TN752 power unit<br />

circuit pack, replace the pack. If the <strong>test</strong> fails on more than 1 port, check<br />

for <strong>error</strong>s on the TONE-BD or the TONE-PT. If <strong>error</strong>s exist, take<br />

appropriate actions. When the tone <strong>error</strong>s are cleared, rerun the <strong>test</strong>.<br />

1150 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

4 of 5