TBRI-PT (ISDN Trunk-Side BRI Port)<br />

otherwise stated, the cause values are D-Chel events. The Aux Data field shows which port<br />

caused the <strong>error</strong>.<br />

Table 256: Aux Data Values for Error 3841–3942<br />

Aux Data<br />

Value<br />

Type of Problem Meaning<br />

2 admin No route to specific transit network<br />

3 admin No route to destination (or Germany bcap not imp)<br />

6 admin Chel unacceptable<br />

18 switch problems No user responding<br />

38 switch problems Network failure<br />

50 subscription Requested facility not subscribed<br />

52 admin Outgoing calls barred<br />

54 admin Incoming calls barred<br />

62 subscription Service not authorized<br />

63 admin/sub Service/option not available<br />

65 admin/sub Bearer capability not implemented<br />

66 admin/sub Chel type not implemented<br />

69 admin/sub Requested facility not implemented<br />

70 admin/sub Only restricted digital BC available<br />

79 admin Service/option not implemented<br />

88 admin Incompatible destination<br />

102 switch problems Recovery on timer expired<br />

Issue 5 May 2009 947