Table 65: CAB-MTCE Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

1025 (e) Reset Test (#1545) MIN ON <strong>test</strong> maintenance location<br />

1281 (f) Environmental<br />

Maintenance<br />

Initialization Test<br />

(#1548)<br />

On/Off<br />

Board<br />

Notes:<br />

a. Error Type 1—When a TN2312AP IPSI is inserted into a CMC1 or G650 Media Gateway, a<br />

minor alarm is raised. Full environmental maintenance is NOT available. Replace the<br />

TN2312AP IPSI with a TN2312BP IPSI. NOTE: A TN2312AP inserted in a G600 media<br />

gateway does NOT raise any alarm or <strong>error</strong>.<br />

b. Error Type 257—The <strong>test</strong> is unable to communicate with the TN2312BP IPSI board. NOTE:<br />

The board must be a TN2312BP IPSI for this <strong>test</strong> to run.<br />

c. Error Type 513—The TN2312BP sent a message with an unknown op-code in response to<br />

the <strong>test</strong>. The unknown op-code is recorded under Aux Data.<br />

d. Error Type 769—The TN2312BP sent a message with a valid op-code but some other part<br />

of the message was indecipherable. The op-code with the <strong>error</strong> is recorded under Aux Data.<br />

e. Error Type 1025—An attempt to reset environmental maintenance was unsuccessful.<br />

f. Error Type 1281—Environmental initialization failed. Run the Reset Environmental<br />

Maintenance Test (#1545), which calls the Environmental Maintenance Initialization Test<br />

(#1548).<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

MIN ON reset maintenance location<br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of investigation Short <strong>test</strong><br />

sequence<br />

1. D = Destructive, ND = Nondestructive<br />

Recommended Action<br />

Long <strong>test</strong><br />

sequence<br />

240 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

D/ND 1<br />

Correct Board Test (#1546) X X ND<br />

Sanity Test (#1547) X X ND<br />

Reset Environmental Maintenance Test (#1545) X D