Error log entries <strong>and</strong> recommended actions<br />

Table 22: -PT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated <strong>test</strong> Alarm<br />

Level<br />

On/Off<br />

Board<br />

-PT (Announcement Port)<br />

Recommended action<br />

0 (a) 0 Any Any Any <strong>test</strong> port location<br />

1 Playback Speech<br />

Memory Array<br />

(PSMA) Test (#206)<br />

MIN ON <strong>test</strong> port location r 3<br />

18 0 The port was busied<br />

out<br />

WRN OFF release port location<br />

130 (b) None WRN ON <strong>test</strong> port location<br />

257 Chel Administration<br />

Memory Array<br />

(CAMA) Test (#205)<br />

17667 inline <strong>error</strong><br />

513 140AY Chel Sanity<br />

Inquiry Test (#222)<br />

17684 inline <strong>error</strong><br />

769 (c) None<br />

MINOR ON <strong>test</strong> port location l r 3<br />

MINOR ON <strong>test</strong> port location r 3<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If all <strong>test</strong>s pass, run the long <strong>test</strong> sequence.<br />

Refer to the appropriate <strong>test</strong> description <strong>and</strong> follow the recommended procedures.<br />

b. Error Type 130: the circuit pack has been removed or has been insane for more than 11<br />

minutes. To clear the <strong>error</strong>, reinsert or replace the circuit pack.<br />

c. Error Type 769 is logged <strong>and</strong> the port is alarmed when an alarm is raised on the<br />

announcement circuit pack because of a faulty condition with a common circuit pack<br />

resource. Any one of the following alarmed <strong>error</strong>s on the announcement circuit pack causes<br />

this <strong>error</strong> to be logged against the announcement Port: 1793, 2049, 2305, 2561. Follow the<br />

-BD (Announcement circuit pack) repair procedures to resolve these alarms. When the<br />

corresponding circuit pack alarm is cleared, this alarm clears.<br />

Issue 5 May 2009 97