Notes:<br />

When problems persist, use reset board to reset the DS1 converter circuit pack. This may<br />

temporarily resolve the <strong>error</strong> condition <strong>and</strong> restore service until further assistance is provided.<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its recommended procedures.<br />

b. Error Type 1: A major failure occurred on the DS1 interface hardware on the DS1<br />

converter circuit pack associated with this DS1 facility. Replace the DS1 converter circuit<br />

pack.<br />

c. Error Type 18: the DS1 facility has been busied out via the busyout ds1-facility<br />

comm<strong>and</strong>. To resolve this <strong>error</strong>, release the DS1 facility via release ds1-facility.<br />

d. Error Type 257: A minor failure occurred on the DS1 interface hardware on the DS1<br />

converter circuit pack associated with this DS1 facility. Replace the DS1 converter circuit<br />

pack.<br />

e. Error Type 513: DS1 converter circuit packs in this DS1 converter complex do not match in<br />

their framing formats or line coding formats.<br />

Aux Data 1 indicates that the framing formats (ESF or D4) do not match. For TN574 DS1<br />

converter boards, the framing mode is administered on the fiber-link screen. The TN1654<br />

DS1 converter has option switches located on the component side of the circuit pack. If T1<br />

operation is selected via the first switch, four additional switches are used to select the<br />

framing mode for each facility. The Framing Mode field on the fiber-link screen is<br />

display-only for the TN1654 boards. It displays what the switch is set to for the DS1 facility.<br />

It cot be administered.<br />

Aux Data 2 indicates that the line coding formats do not match. Line Coding is an<br />

administrable value on the fiber-link screen. The line coding options are ami-zcs or b8zs<br />

for TN574 boards <strong>and</strong> TN1654 boards in T1 mode. For TN1654 boards in E1 mode, the<br />

line coding options are ami-basic or hdb3.<br />

This <strong>error</strong> should clear in 15 minutes.<br />

1. Verify that DS1 facility <strong>and</strong> the network is using the same line coding (ami-zcs, b8zs,<br />

ami-basic, hdb3) <strong>and</strong> framing mode (ESF, D4). Use list fiber-link <strong>and</strong><br />

display fiber-link to check the values for this DS1 facility. Contact T1 Network<br />

Service to check the modes used by the network.<br />

If the framing mode format differs on boards in a TN1654 DS1 converter complex, the<br />

DS1 converter board that has its option switch set incorrectly will have to be physically<br />

removed from the system in order to set the facility framing mode switch properly.<br />

2. If the problem persists, reset both DS1 converter circuit packs via the reset board.<br />

3. If the problem still persists, replace this DS1 converter circuit pack.<br />

4. If the problem still persists, replace the DS1 converter circuit pack at the other end of<br />

the DS1 converter complex.<br />

f. Error Type 856: More than 88 negative <strong>and</strong>/or positive slip <strong>error</strong>s occurred. This <strong>error</strong><br />

clears when there are no slips for 1 hour.<br />

364 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers