Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 305: SAKI Sanity Test (#53) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

1 FAIL The circuit pack or media module failed to reset.<br />

1. Enter the comm<strong>and</strong> again.<br />

2. If the problem persists, replace the circuit pack or media module.<br />

2 FAIL The circuit pack or media module failed to restart.<br />

1. Enter reset board location again.<br />

2. If the problem persists, escalate this problem.<br />

ANY NO<br />

BOARD<br />

Description / Recommendation<br />

PASS The circuit pack or media module initialized correctly.<br />

See NO BOARD for the repair procedures.<br />

Analog Electronic Power Feed Test (#56)<br />

The <strong>test</strong> requests that the EPF be turned on for a given port. The hardware then attempts to turn<br />

on that port’s station power unit. If no current is drawn, the station is probably not connected. If<br />

an overcurrent condition is sensed (too much current is drawn), a short may exist in the loop or<br />

the voice terminal may be defective. The <strong>test</strong> results indicate either the EPF was turned on<br />

successfully with no problems or an overcurrent condition exists. This <strong>test</strong> is repeated after a 5<br />

second delay. If either <strong>test</strong> is not successful, the <strong>test</strong> aborts.<br />

Although this <strong>test</strong> will never actually return a fail result except for the internal system <strong>error</strong>, an<br />

Error Type 257 entry will be made in the <strong>error</strong> log after the <strong>test</strong> has completed if the overcurrent<br />

case is detected by the hardware.<br />

This <strong>test</strong> is run on HYB-LINE (Hybrid Line) <strong>and</strong> MET-LINE (MET Line).<br />

1162 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />