Nonvolatile Memory<br />

Nonvolatile memory stores downloadable parameters in programmable terminals. Once the<br />

terminal is downloaded, it is not be necessary to download it again, even if power is removed<br />

from the terminal. If nonvolatile memory fails with power still present, the terminal reverts to its<br />

default factory settings except for its A-law/mu-law comp<strong>and</strong>ing settings which are stored in<br />

RAM. If power is removed after the nonvolatile memory fails, the terminal reverts to its factory<br />

default settings.<br />

Note: The<br />

Note:<br />

mu-law comp<strong>and</strong>ing mode is assigned as a default setting at the factory. For<br />

the United States, a programmable terminal can place calls even though it has<br />

not been downloaded from the system.<br />

Download Actions<br />

There are several different scenarios which causes a terminal to be downloaded. These can<br />

occur as part of background maintenance activity or on dem<strong>and</strong> from the SAT (System Access<br />

Terminal) or from a station.<br />

For the background actions described below, the terminal downloads automatically if a<br />

download retry flag for the terminal is set in software. This flag is set at the time translation is<br />

loaded at boot time, when the translation that affects the parameters of a terminal is changed as<br />

part of system administration actions, or when a port is inserted in software as a result of board<br />

insertion or translation change.<br />

Automatic Download Actions<br />

Note: It<br />

1. System Reboot/Restart<br />

A global download action is initiated when periodic maintenance <strong>test</strong>s begin after a system<br />

reboot/restart, regardless of whether the parameters have been downloaded previously.<br />

2. Periodic <strong>test</strong>s<br />

If the download flag is still set when periodic <strong>test</strong>s are run on a terminal, a download action<br />

occurs. This action is required in case a terminal could not be downloaded previously,<br />

because the terminal was off-hook when the:<br />

● system first booted<br />

or<br />

● translations associated with downloadable parameters were changed.<br />

Note:<br />

may take more than an hour for periodic <strong>test</strong>s to reach the terminal that needs<br />

to be downloaded.<br />

804 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers