CONFIG (System Configuration)<br />

’1’ to the Aux Data value. For example, if the Aux Data value is ’0’, the port network<br />

number is 1. If the Aux Data value is ’29’, the port network number is 30.<br />

The Error Type field specifies the carrier <strong>and</strong> slot location of the circuit pack that caused<br />

the <strong>error</strong> as indicated in Table 78: Converting Error Types To Carrier Locations. If the<br />

Error Type is greater than 1000, subtract 1000 from the Error Type field before consulting<br />

the table.<br />

S8700 Fiber-PNC:Before proceeding, if multiple CONFIG <strong>error</strong>s are simultaneously logged<br />

with an Aux Data of 1, investigate any EXP-INTF (Expansion Interface Circuit Pack) <strong>error</strong>s.<br />

Once the port’s circuit-pack location has been determined, use list configuration<br />

all to determine whether the circuit pack is inserted. If the circuit pack has already been<br />

inserted but the <strong>error</strong> persists, replace the circuit pack. If not, insert the pack.<br />

Table 78: Converting Error Types To Carrier Locations 1 of 5<br />

Error Type Carrier Location<br />

1 (a)<br />

2 E01<br />

3 E02<br />

4 E03<br />

5 E04<br />

6 E05<br />

7 E06<br />

8 E07<br />

9 E08<br />

10 E09<br />

11 E10<br />

12 E11<br />

13 E12<br />

14 E13<br />

15 E14<br />

16 E15<br />

17 E16<br />

18 E17<br />

1 of 5<br />