Ground Start Operation<br />

CO-TRK (Analog CO Trunk)<br />

Idle state:<br />

Tip = open, Ring = CO Battery<br />

Outgoing Call:<br />

PBX Off-Hook (Seize message): Places ground on Ring<br />

CO response: Places ground on Tip<br />

PBX response: Close the loop<br />

CO response: Provide loop current<br />

PBX response: Dial out digits<br />

PBX On-Hook first (Drop message): Open the Tip-Ring Loop, no loop current<br />

CO response: Open circuit on Tip<br />

CO On-Hook first (Disconnect): Open circuit on Tip, no loop current<br />

PBX response: Open Tip-Ring loop<br />

Incoming Call:<br />

CO Off-Hook (Seizure): CO applies ground on Tip <strong>and</strong> applies ringing voltage to the Ring<br />

lead.<br />

PBX response: Make trunk busy for outgoing calls<br />

CO Ringing: CO applies ringing voltage to the Ring lead.<br />

PBX response: Detect ringing, ring destination (Attendant, hunt group, etc.)<br />

PBX Off-Hook (Answer message): Close loop<br />

CO response: Trip ringing, provide loop current<br />

PBX On-Hook first (Drop message): Open the Tip-Ring Loop, no loop current<br />

CO response: Open circuit on Tip<br />

CO On-Hook first (Disconnect): Open circuit on Tip, no loop current<br />