Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 428: Secondary Signaling Link Hardware Check (#639) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

1132 ABORT The Secondary D-chel is not administered for this Signaling Group. This is a<br />

NORMAL ABORT. Only a Primary D-Chel must be administered for a<br />

Signaling Group. No action is necessary.<br />

4 FAIL There is a problem with the Processor Interface Link. No DS1 ISDN Trunk<br />

(B-Chel) or Wideb<strong>and</strong> PRI Endpoint calls can be made until the problem is<br />

resolved.<br />

1. Display the Communication-Interface Links Form with display<br />

communication-interface to determine which link is down. Find<br />

the one that matches the DS1 Interface circuit pack on which this<br />

ISDN-PRI Signaling Link Port resides, <strong>and</strong> refer to PKT-INT (Packet<br />

Interface).<br />

8 FAIL There is a problem with the TN464 UDS1 Interface circuit pack, the DS1<br />

Interface Media Module, or the ISDN-PRI Secondary Signaling Chel<br />

(D-chel). No ISDN trunk or PRI endpoint calls can be made until the<br />

problem is resolved.<br />

1. Consult the procedures for the TN464 circuit pack for UDS1-BD<br />

(UDS1 Interface Circuit Pack), DS1-BD (DS1 Interface Circuit Pack),<br />

or MG-DS1 (DS1 Interface Media Module), <strong>and</strong> the ISDN-PLK<br />

(ISDN-PRI Signaling Link Port).<br />

PASS The basic physical connectivity of the Signaling Group’s Secondary D-Chel<br />

is intact <strong>and</strong> functional. Try this <strong>test</strong> repeatedly to ensure the link is up <strong>and</strong><br />

to uncover any transitory problems.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />

Signaling Link Board Check (#643)<br />

This <strong>test</strong> checks the health of the critical ATM TN230X circuit pack, DS1 Interface circuit pack,<br />

or DS1Interface media module hardware components required by the signaling link.<br />

This <strong>test</strong> runs on ATM-DCH (ATM D-Chel Port) <strong>and</strong> ISDN-PLK (ISDN-PRI Signaling Link Port).<br />