● If the problem still exists, switch the Tone-Clock in the slave port network back to<br />

the previous configuration, then perform a PNC interchange using reset pnc<br />

interchange.<br />

● If the problem still exists, switch the PNC back to the previous configuration using<br />

reset pnc interchange. Switch the Tone-Clock circuit packs in the master<br />

port network using set tone-clock location.<br />

● If the problem still exists, switch the Tone-Clock circuit packs in the master port<br />

network back to the previous configuration using set tone-clock location.<br />

● Replace the active Expansion Interface circuit pack in the master port network.<br />

● In a CSS configuration, replace the Switch Node Interface circuit pack connected<br />

to the active Expansion Interface circuit pack in the master port network. Use list<br />

fiber-link to determine the Switch Node Interface circuit pack that is<br />

connected to the active Expansion Interface circuit pack in the master port<br />

network.<br />

● If the system’s synchronization reference is a Tone-Clock circuit pack or a<br />

Stratum-3 clock, follow normal escalation procedures.<br />

If the system’s primary synchronization reference is a DS1 Interface circuit pack,<br />

assign a different DS1 Interface as the primary reference. If the problem persists<br />

<strong>and</strong> slip <strong>error</strong>s remain, follow the procedures in the troubleshooting section above.<br />

6. For unduplicated Tone-Clock circuit packs in a slave port network:<br />

● Enter set tone-clock location to switch the Tone-Clock in the master port<br />

network.<br />

● If the problem still exists, enter set tone-clock location to switch the<br />

Tone-Clocks in the master port network back to their previous configuration.<br />

Enter <strong>test</strong> tone-clock location long to <strong>test</strong> the Tone-Clock in the master<br />

<strong>and</strong> slave port networks.<br />

Check the Error Log for TDM-CLK <strong>error</strong>s <strong>and</strong> verify that TDM Bus Clock Circuit<br />

Status Inquiry <strong>test</strong> (#148) passes.<br />

If Test #148 fails with an Error Code 2–32, see TDM-CLK (TDM Bus Clock) to<br />

resolve the problem. If not, continue with the following steps.<br />

● If the master <strong>and</strong> slave Tone-Clock circuit packs do not fail TDM Bus Clock Test<br />

#150 (TDM Bus Clock PPM Inquiry <strong>test</strong>), replace the Expansion Interface circuit<br />

packs that have EXP-INTF <strong>error</strong> 2305.<br />

● If the system synchronization reference is a Tone-Clock circuit pack <strong>and</strong> the<br />

master Tone-Clock circuit pack fails TDM Bus Clock Test #150, follow the steps<br />

listed in “TDM-CLK” to replace the master Tone-Clock circuit pack.<br />

920 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers