SNI Fiber Out of Frame Query Test (#989)<br />

SNI Fiber Out of Frame Query Test (#989)<br />

This <strong>test</strong> performs a non-destructive facility <strong>test</strong> of the SNI. The SNI circuit pack reports whether<br />

a fiber out of frame condition exists, whether a loss of signal condition exists, <strong>and</strong> whether the<br />

lightwave transceiver is present.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● FIBER-LK (Fiber Link)<br />

● SNI-BD (SNI Circuit Pack)<br />

● SNI-PEER (SNI Peer Link)<br />

Table 471: SNI Fiber Out of Frame Query Test (#989) 1 of 8<br />

Error<br />

Code<br />

1415<br />

1416<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT The lightwave transceiver is absent from Endpoint 1.<br />

The lightwave transceiver is absent from Endpoint 2.<br />

1. Enter list fiber-link to display fiber link endpoints.<br />

2. If a lightwave transceiver should not be present, do nothing. For<br />

example, an SNI connected to a DS1C circuit pack or an SNI with a<br />

metallic connection does not have a lightwave transceiver.<br />

3. Otherwise, check the lightwave transceiver connections. Check that<br />

the lightwave transceivers are of the same type, that is, both are<br />

9823a or both are 9823b. If they are not the same type, replace one<br />

of the lightwave transceivers:<br />

● 9823a is used for distances up to 4900 feet.<br />

● 9823b is used for distances up to 25,000 feet.<br />

4. If the <strong>test</strong> continues to abort, replace the SNI circuit pack.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

2300 The downlink message necessary to run this <strong>test</strong> could not be sent.<br />

2301 The timer could not be set before sending the downlink message.<br />

2304 SNI circuit pack is not able to run the <strong>test</strong> requested by software.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />