Incoming Call<br />

1. CO Applies Ringing Voltage<br />

2. PBX Response: Detect ringing current<br />

3. PBX Off-Hook (Answer Message): Close loop<br />

4. CO Response: Trip ringing, provide loop current<br />

5. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current<br />

6. CO Response: CO goes to idle state (see Note)<br />

Direct Inward Dialing (DID) (Loop Start)<br />

1. CO Applies Ringing Voltage<br />

2. PBX Response: Detect ringing current <strong>and</strong> close loop<br />

3. CO Response: Send DTMF digits<br />

4. PBX Response: Acknowledge of Number dialed <strong>and</strong> open loop<br />

5. PBX Off-Hook (Answer Message): Close loop<br />

6. CO Response: Trip ringing, provide loop current<br />

7. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current<br />

8. CO Response: CO goes to idle state (see Note)<br />

Note: CO<br />

Note:<br />

does not normally provide an On-Hook (Disconnect) signal.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 88: DIOD-TRK Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

338 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> port sh<br />

15 (b) any Port Audit Update Test (#36)<br />

18 0 busyout trunk grp/mbr WRN release trunk<br />

769 (c) 57392 MAJ<br />

MIN<br />

WRN 1<br />

ON<br />

1 of 2