EXT-DEV ADMIN? Y (External Device Alarm)<br />

S8700 series / S8500<br />

Note: Use<br />

EXT-DEV ADMIN? Y (External Device Alarm)<br />

Note:<br />

this MO when the External Device Alarm Admin field on the change<br />

system-parameters customer-options screen is y. You must have INADS<br />

or INIT login permissions to administer EXT-DEV Alarm.<br />

S8700 series / S8500<br />

Each PN’s Maintenance circuit pack has two alarm ports that connect to such external devices<br />

as uninterruptible power supplies (UPSs) or adjuncts (e.g., AUDIX).<br />

Certain conditions on the external device close the contacts on the alarm leads to notify the<br />

switch that in turn originates an EXT-DEV alarm. One set of leads generates a major alarm; the<br />

other set generates a minor alarm.<br />

The special locations UUmajor <strong>and</strong> UUminor designate the major or minor Maintenance<br />

board’s alarm connection for cabinet UU. The major/minor designation specifies the port, not<br />

the alarm level associated with the connection; for example, the “major” port can be<br />

administered as a major, minor, or warning alarm, <strong>and</strong> the “minor” port can be administered as a<br />

major, minor, or warning alarm. In addition Analog line ports can also be administered as<br />

external device alarms.<br />

Note: An<br />

MO Name in<br />

Log<br />

Alarm<br />

Level<br />

EXT-DEV MAJ<br />

MIN<br />

WRN<br />

Initial Comm<strong>and</strong> to Run 1<br />

1. UU is a cabinet number determined in the Port field of the Alarm or Error Log.<br />

Full Name of MO<br />

<strong>test</strong> eda-external-device-alrm UU External Device Alarm<br />

Note:<br />

un-administered Maintenance board’s external device alarm port, that is<br />

sensing a contact closure will have an entry in the Error Log <strong>and</strong> in the Alarm Log.<br />

The alarm receiver will not receive warning alarms.<br />

Issue 5 May 2009 459