Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 438: FIBER-LK Configuration Audit (#759) 9 of 10<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

238 FAIL The physical location of SNI Endpoint 2’s neighbor does not match its<br />

administered location.<br />

1. Enter list fiber-link to see a fiber link’s endpoints. One<br />

location (carrier <strong>and</strong> slot) is assigned for the endpoint’s neighbor, but<br />

it physically resides in another location.<br />

2. Enter list fiber-link <strong>and</strong> verify that the fiber-optic <strong>and</strong> metallic<br />

cables are installed as administered.<br />

3. If the problem does not seem to be caused by either a<br />

physical-connection or an administration problem, replace the<br />

neighbor circuit pack. The neighbor circuit pack may have a<br />

hardware problem causing it to report a wrong Angel address<br />

(physical carrier/slot address) to software.<br />

239 FAIL The SNI Endpoint 2 is assigned to be connected to a DS1 converter, but is<br />

not physically connected to one.<br />

1. Enter list fiber-link to see a fiber link’s endpoints.<br />

If this SNI endpoint should be connected to a DS1 converter:<br />

1. Enter list fiber-link to verify that the fiber-optic cable <strong>and</strong>/or<br />

metallic cable connections are installed as assigned.<br />

If not, change administration to remove the DS1 converter complex from<br />

the SNI’s fiber link:<br />

1. Enter list fiber-link to locate this SNI endpoint’s fiber<br />

2. Enter remove fiber-link for this SNI endpoint’s fiber<br />

3. Enter add fiber-link to replace the fiber without assigning the<br />

DS1 converter complex.<br />

1468 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />