Clear Firmware-Counters Comm<strong>and</strong><br />

DS1 converter firmware generates <strong>error</strong> reports autonomously. This takes place independently<br />

of dem<strong>and</strong> <strong>test</strong>s. The <strong>test</strong> board location clear comm<strong>and</strong> will not affect the <strong>error</strong> status<br />

reported by firmware. The clear firmware-counters comm<strong>and</strong> clears every on-board<br />

firmware-detected <strong>error</strong> unconditionally.<br />

The clear firmware-counters location comm<strong>and</strong> sends a downlink message to the<br />

DS1 converter circuit packs, causing them to clear out their firmware <strong>error</strong> counters <strong>and</strong> failure<br />

databases. Once the firmware failure database is cleared, the Failure Audit Test (#949) will<br />

pass. If problems still exist, the firmware will increment its <strong>error</strong> counters <strong>and</strong> the failure audit<br />

<strong>test</strong> will begin failing again.<br />

This comm<strong>and</strong> should not be used as a replacement for the repair procedures associated with<br />

the <strong>error</strong> log entries. This comm<strong>and</strong> may be useful if a problem has been fixed <strong>and</strong> off-board<br />

alarms associated with the problem are still active.<br />

Downtime Required when Upgrading to<br />

TN1654 DS1 Converter Circuit Packs<br />

WARNING: Upgrading from TN574 DS1 converter circuit packs to TN1654 DS1 converter<br />

circuit packs will require down time for the affected PN.<br />

The TN1654 DS1 Converter circuit pack is not compatible with the TN573 SNI circuit pack, the<br />

TN574 DS1 converter board, the Y-cable used to connect to the TN574 DS1 converter board or<br />

pre-G3V5 software. All DS1 converter boards <strong>and</strong> Y-cables must be upgraded. If the PN is<br />

remoted via a Center-Stage Switch, the connected SNI must also be upgraded. A TN573B (or<br />

higher-suffixed) SNI board must be used when connecting to a TN1654 DS1 converter board.<br />

Use remove fiber-link to remove the fiber-link administration for the TN574 DS1<br />

converter complex. Use change circuit-pack show that TN1654 boards are now being<br />

used. Then use add fiber-link to administer the TN1654 DS1 converter complex.<br />

378 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers