Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

● RANL-STA (Remote Analog Line (Station) Port)<br />

Table 301: ONS Ringer Application Test (#48) 1 of 2<br />

Error<br />

Code<br />

1000<br />

1004<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

ABORT System resources required to run this <strong>test</strong> are not available or the port<br />

was seized with a valid call during the <strong>test</strong>.<br />

1. Enter display port location to determine the station<br />

extension.<br />

2. Enter status station extension to determine the service<br />

state of the port. If the port is in use, wait until the port is idle.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT This <strong>test</strong> is not applicable for this type of port. This <strong>error</strong> can be ignored.<br />

1008 ABORT Could not allocate a ringing circuit. Either every ringing circuit is in use,<br />

or the ringing generator is defective or incorrectly wired.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, look for RING-GEN <strong>error</strong>s in the Error<br />

Log. If an ABORT 1008 occurs for this <strong>test</strong> on other circuit packs as<br />

well, then the ringing generator may be defective or incorrectly<br />

wired See RING-GEN (Analog Ring Generator).<br />

3. If ABORT 1008 does not occur on other ports, then all four ring<br />

phases are in use.<br />

1018 ABORT The <strong>test</strong> has been disabled by administration. Determine why the Test<br />

field on the change station screen has been set to n for this station. It<br />

may be due to the brief ringing disturbance that this <strong>test</strong> may cause.<br />

1. To enable the <strong>test</strong> for the particular analog station, enter<br />

change station extension <strong>and</strong> set the Test field to y.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1152 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />