ASAI-PT (ASAI Port)<br />

d. Error Type 1537: The port received an invalid frame over the D-Chel. This <strong>error</strong> is most<br />

likely due to a problem with the wiring to the set or adjunct, interference on the wiring due to<br />

a noise source, or no termination (an open circuit). It usually does not indicate a problem<br />

with the circuit pack.<br />

● Check the wiring to the endpoints or the adjunct.<br />

● If the problem persists, replace the endpoints or adjuncts.<br />

e. Error Type 3841: a Layer 1 Transmission <strong>error</strong> is detected for the port. Run the long <strong>test</strong><br />

sequence, <strong>and</strong> note the results of the Layer 1 Transmission Error Counter Test (#624).<br />

f. Error Type 3844: the circuit pack detects an overflow of its receive buffers. Run the long<br />

<strong>test</strong> sequence, <strong>and</strong> note the results of the Receive FIFO Error Counter Test (#625).<br />

g. Error Type 3845: the BRI Port Local LAN Looparound Test (#618) fails. Run the long <strong>test</strong><br />

sequence, <strong>and</strong> note the results of Test #618.<br />

h. Error Type 3846: the TEI (Terminal Endpoint Identifier) administered for the ASAI endpoint<br />

most likely does not match the TEI administered in the ASAI adjunct. Check the switch<br />

administration of the TEI against that of the adjunct, <strong>and</strong> make sure that both are using the<br />

same TEI.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

BRI Port Local LAN Looparound Test (#618) X D<br />

1. D = Destructive, ND = Nondestructive<br />

D/ND 1<br />

Level 1 Status Inquiry Test (#621) X X ND<br />

CRC Error Counter Test (#623) X ND<br />

Layer 1 Transmission Error Counter Test (#624) X ND<br />

Receive FIFO Error Counter Test (#625) X ND<br />

Clear Error Counters Test (#270) X X ND<br />

Issue 5 May 2009 113