ATM-EI (Expansion Interface Circuit Pack)<br />

● The fiber between the ATM switch <strong>and</strong> the ATM-EI is too long (greater than 2 km for<br />

multimode fiber). Use loopback to see if the fiber is corrupting the cells.<br />

● Some other ATM-EI board is not receiving the cells properly.<br />

● The intervening ATM switch is dropping the ATM cells due to a shortage of b<strong>and</strong>width,<br />

or the server is using more than the subscribed b<strong>and</strong>width.<br />

Error Type 771: The ATM switch is sending cells with unknown VPI <strong>and</strong> VCI address<br />

(wrong connection).<br />

1. Ensure that the address translations are correct.<br />

j. Error Types 1024-1151: These <strong>error</strong>s represent problems detected by the ATM-EI board in<br />

response to SETUP <strong>and</strong> ADDPARTY requests from software.<br />

● The Error Types <strong>and</strong> <strong>descriptions</strong> are in Table 35: ATM Error Types 1024 - 1151.<br />

● Aux Data values represent PN <strong>and</strong> Angel numbers <strong>and</strong> are in Table 36: Error Type<br />

1024-1151 Converted Aux Data Values.<br />

Table 35: ATM Error Types 1024 - 1151 1 of 3<br />

Error<br />

Type<br />

Description General problem<br />

1024 Next node unreachable ATM protocol stack on<br />

ATM-EI3 circuit pack<br />

1056 DTL Transit not my node ID<br />

1 of 3<br />