Table 310: Analog Line Station Lamp Update Test (#60) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Analog Line Station Lamp Update Test (#60)<br />

1 ABORT This port may have been busied out.<br />

1. Look in the Error Log for Error Type 18 (port busied out) for this port.<br />

If this Error Type is present, then release the port using release<br />

station extension <strong>and</strong> run the <strong>test</strong> again.<br />

2. Make sure the terminal is connected.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

3 ABORT The station is in ready-for-service or out-of-service state. This may be due<br />

to wiring or an unplugged or defective set.<br />

1. Make sure the terminal is connected <strong>and</strong> the wiring is correct.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port may<br />

be busy with a valid call.<br />

1. Enter display port location to determine the station extension<br />

of the port.<br />

2. Enter status station to determine the service state of the port. If<br />

the port is in use, wait until the port is idle before <strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1392 ABORT This port is a TTI port. The <strong>test</strong> does not run on TTI ports.<br />

1. Verify that the port is a TTI port using either display port (the<br />

port is a TTI port) or list config (shows a t for the port).<br />

2. If list config or display port indicate that the port is not a<br />

TTI port, escalate the problem. If both comm<strong>and</strong>s indicate that the<br />

port is a TTI port, the abort is correct, <strong>and</strong> no action is necessary.<br />

FAIL Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

PASS Analog Line Station Lamp Update Test completed successfully.<br />

1. If complaints persist, investigate by using other circuit pack <strong>test</strong>s,<br />

<strong>and</strong> by examining the station, wiring, <strong>and</strong> connections.<br />

1 of 2<br />

Issue 5 May 2009 1171