Error log entries <strong>and</strong> recommended actions<br />

XXX-BD (Common Port Circuit Pack/Media Module)<br />

Table 281: Common Port Circuit Pack Maintenance Error Log Entries<br />

Error<br />

Type<br />

0 1<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 Any Any Any <strong>test</strong> board location<br />

1 (a) 0 Circuit pack or Media Module<br />

removed or SAKI Sanity (#53)<br />

MIN ON<br />

18 (b) 0 busyout board location WRN OFF release board location<br />

23 (c) 0 None WRN OFF<br />

36 (d) 4368 none<br />

125 (e) None MIN ON<br />

217 (f) 0 None WRN ON<br />

257 (g) 65535 Control Chel Looparound Test<br />

(#52)<br />

MIN ON <strong>test</strong> board location r 20<br />

267 (h) 0 None WRN ON<br />

513 (i) Any None MIN ON <strong>test</strong> board location<br />

769 (j) 4358 None<br />

1025 (k) 4363 NPE Audit Test (#50) <strong>test</strong> board location l r 20<br />

1281 (l) Ringing Application Test (#51) MIN ON <strong>test</strong> board location r 2<br />

1412 (m)<br />

1538 (n) Any None WRN<br />

MIN<br />

ON<br />

1793 (o) Neon Test (#220) MIN ON <strong>test</strong> board location r 2<br />

3840 (p) Any None<br />

3999 (q) Any None<br />

1. Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong> sequence. Refer to each<br />

appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended procedures.<br />