BRI-BD (ISDN-BRI Line Circuit Pack)<br />

m. Error Types 4096, 4097, 4098, 4099, 4100, 4101: the circuit pack received a bad control<br />

chel message from the switch. Not service-affecting, no action is required. The auxiliary<br />

data identifies the <strong>error</strong> events.<br />

Error Type 4096: Bad major heading<br />

Error Type 4097: Bad port number<br />

Error Type 4098: Bad data<br />

Error Type 4099: Bad sub-qualifier<br />

Error Type 4100: State inconsistency<br />

Error Type 4101: Inconsistent downlink message<br />

n. Error Type 3843: bad translation RAM detected, but call continues by using another<br />

translation location. This <strong>error</strong> is not service-affecting. No action is required.<br />

o. Error Type 3999: the circuit pack sent a large number of control chel messages to the<br />

switch in a short period of time.<br />

If Error Type 1538 is also present, the circuit pack was taken out-of-service due to<br />

hyperactivity.<br />

If Error Type 1538 absent, the circuit pack was not taken out-of-service, but has generated<br />

50% of the messages necessary to be considered hyperactive. This may be normal during<br />

heavy traffic periods. If traffic is light, it may indicate a problem with the circuit pack or the<br />

equipment attached to it.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

D/ND 1<br />

Control Chel Looparound Test (#52) X X ND<br />

NPE Audit Test (#50) X ND<br />

LANBIC Receive Parity Error Counter Test (#595) X ND<br />

1. D = Destructive; ND = Nondestructive<br />