Table 535: Echo Canceller Test (#1420)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Echo Canceller Test (#1420)<br />

1015 ABORT The board is not busied out.<br />

1. If the board is not in use, enter busyout board location<br />

2. Retry the <strong>test</strong>.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time. This may<br />

be due to hyperactivity.<br />

1. Enter display <strong>error</strong>s on the SAT.<br />

2. If Error Type 1538 appears in the <strong>error</strong> log for this board, see<br />

Hyperactive DS1/UDS1 Interface Circuit Pack/Media Module for the<br />

repair procedures. Otherwise, retry the <strong>test</strong> at 1-minute intervals up<br />

to 5 times.<br />

2012<br />

2100<br />

2500<br />

1400<br />

1401<br />

ABORT Internal system <strong>error</strong>.<br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The Echo Canceller <strong>test</strong> failed. Echo Cancellation is no longer being<br />

supplied by the board.<br />

● Error 1400 - Echo canceller function <strong>test</strong> failed.<br />

● Error 1401 - Echo canceller memory <strong>test</strong> failed.<br />

Clear the alarm using <strong>test</strong> board location long. If the <strong>test</strong> still<br />

fails, replace the board. The board can still be used for a T1/E1 line<br />

interface without echo cancellation. This capability provides limited service<br />

for the customer until the board can be changed out.<br />

PASS The Echo Cancellation feature is functioning properly.<br />

1. Enter release board location to put the board back in<br />

service.<br />

0 NO<br />

BOARD<br />

See NO BOARD for the repair procedures.<br />

Issue 5 May 2009 1673