This <strong>test</strong> is run for ANL-LINE (8-Port Analog Line).<br />

Table 300: Looparound <strong>and</strong> Conference Test (#47) 1 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Looparound <strong>and</strong> Conference Test (#47)<br />

ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

7 ABORT The port was seized by a user for a valid call.<br />

1. Enter display port location to determine the station’s<br />

extension.<br />

2. Enter status station extension to determine the service<br />

state of the port. If the port is in use, wait until the port is idle before<br />

re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> were not available. The port<br />

may be busy with a valid call. This could be a Music-on-Hold port.<br />

1. Enter display port location to determine the station’s<br />

extension.<br />

2. Enter status station extension to determine the service<br />

state of the port. If the port is in use, wait until the port is idle before<br />

re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may<br />

be under heavy traffic conditions, or it may have time slots<br />

out-of-service due to TDM-BUS <strong>error</strong>s. A system is considered under<br />

heavy traffic when the Call Processing Occupancy is greater than 50%<br />

or when the System Management <strong>and</strong> the Call Processing Occupancies<br />

together exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display <strong>error</strong>s <strong>and</strong> resolve any TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 of 5<br />

Issue 5 May 2009 1147