Table 185: MG-DS1 Error Log Entries 3 of 3<br />

Error Type Aux<br />

Data<br />

1795 Any Blue Alarm<br />

Inquiry (#139)<br />

2049 Any Red Alarm<br />

Inquiry (#140)<br />

2305 Any Yellow Alarm<br />

Inquiry (#141)<br />

2306 Any Yellow Alarm<br />

Inquiry (#141)<br />

2561 Any Major Alarm<br />

Inquiry (#142)<br />

2817 Minor Alarm<br />

Inquiry (#143)<br />

3073 to<br />

3160 (o)<br />

3585 to<br />

3601 (p)<br />

3840 (q) Any<br />

3841 (r) 4358<br />

3842 (s) 46097<br />

3999 (t) Any<br />

Associated Test Alarm<br />

Level<br />

Any Slip Alarm Inquiry<br />

(#144)<br />

Any Misframe Alarm<br />

Inquiry Test<br />

(#145)<br />

MAJ<br />

MIN<br />

WRN<br />

On/Off<br />

Board<br />

Recommended Action<br />

OFF <strong>test</strong> board location<br />

MIN OFF <strong>test</strong> board location<br />

1<br />

WRN<br />

MIN OFF <strong>test</strong> board location<br />

1 WRN<br />

MIN OFF <strong>test</strong> board location<br />

WRN1 MIN OFF <strong>test</strong> board location<br />

1<br />

WRN<br />

MIN OFF <strong>test</strong> board location<br />

WRN1 MIN OFF <strong>test</strong> board location r 6<br />

1<br />

WRN<br />

MIN OFF <strong>test</strong> board location r 6<br />

1 WRN<br />

1. If ports are assigned to the Media Module, then a minor alarm is raised. If no ports are assigned to the<br />

Media Module, then a warning alarm is raised. The alarm is raised after the Media Module has been<br />

missing for a period of 15 minutes. Warning alarms are also raised against any ports administered on the<br />

Media Module.<br />

2. Major alarms on this MO may be downgraded to minor or warning alarms, <strong>and</strong> minor alarms on<br />

this MO may be downgraded to warning alarms based on values set in set options.<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If all <strong>test</strong>s pass, run the long <strong>test</strong> sequence.<br />

Refer to the appropriate <strong>test</strong> description <strong>and</strong> follow the recommended procedures.<br />

b. Error Type 1: the Media Module has totally stopped functioning or is not fully administered.<br />

The alarm is logged about 15 minutes after the Media Module has been removed or<br />

11-minutes after the SAKI Test (#53) fails. To be fully administered, a Media Module must<br />

meet all three of the following conditions:<br />

● Have an entry in the circuit plan using the change media module comm<strong>and</strong><br />

640 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />