Environmental Maintenance Initialization Test (#1548)<br />

When a TN2312BP IPSI is inserted in a G650, Communication Manager sends the following<br />

messages to embedded software (firmware) on the board:<br />

● Enable environmental maintenance<br />

● Enable power supply insertion<br />

● Enable power supply audits<br />

● A query to verify that environmental maintenance is enabled<br />

● A query to verify that power supply insertion is enabled<br />

● A query to verify that power supply audits are enabled<br />

This <strong>test</strong> runs on CAB-MTCE (Media Gateway Maintenance).<br />

.<br />

Table 553: Environmental Maintenance Initialization Test (#1548)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description <strong>and</strong> recommendation<br />

1000 FAIL Internal system <strong>error</strong>.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals up to 3 times.<br />

1986 ABORT Set Emergency Transfer failed.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals up to 3 times.<br />

2000<br />

2033<br />

2500<br />

FAIL No response received within the allowed time.<br />

Internal system <strong>error</strong>.<br />

Internal operation failed. Possible unknown cabinet type.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals up to 3 times.<br />

FAIL The TN2312BP in carrier A is missing. This <strong>test</strong> will also fail if an<br />

incorrect response or no response from firmware is received when the<br />

board is queried.<br />

1. Ensure that there is a TN2312BP in the A carrier.<br />

2. Repeat the comm<strong>and</strong> at one-minute intervals up to 3 times.<br />

PASS Environmental maintenance initialization was successful.<br />

Issue 5 May 2009 1711