Table 116: Expansion Interface Circuit Pack Amber LED Flashing Codes<br />

Condition LED on LED off<br />

FIBER-LK (Fiber Link)<br />

Fiber Out-of-Frame 0.1 second 0.1 second<br />

In frame-No Neighbor (a) 0.5 second 0.5 second<br />

Expansion Interface Active (b) 2 second 0.2 second<br />

Expansion Interface Active (c) Solid on Never off<br />

Expansion Interface St<strong>and</strong>by (d) Never on Solid off<br />

Notes:<br />

a. The fiber is in frame, but no communication exists to the neighbor.<br />

b. This is the normal state for an active PN EI circuit pack that is also the bus master<br />

(expansion Archangel) in the PN.<br />

c. This is the normal state for an active EI circuit pack that is not the bus master (expansion<br />

Archangel) for a PN. This applies only in the direct connect configuration where the EI<br />

circuit pack in a PN connects via a fiber link to an EI circuit pack in the other PN. This state<br />

also applies for an active EI circuit pack located in the PN.<br />

d. This is the normal state for a st<strong>and</strong>by expansion Interface circuit pack in the PN.<br />

For more details about how the EI circuit pack <strong>error</strong> <strong>codes</strong> relate to the LED states, see<br />

EXP-INTF (Expansion Interface Circuit Pack).<br />

Table 117: DS1 Converter Amber LED Flashing Codes<br />

Condition LED on LED off<br />

Fiber out of Frame (a) 0.1 second 0.1 second<br />

In frame, fiber chel is down (b) 0.5 second 0.5 second<br />

In frame, DS1 chel down (c) 1 second 1 second<br />

DS1 converter, no response from server (d) 2 second 0.2 second<br />

DS1 converter active Solid on Never off<br />

DS1 converter st<strong>and</strong>by Never on Solid off<br />

Notes:<br />

a. A Fiber is out of frame or a fiber loss-of-signal condition exists.<br />

b. DS1 converter/fiber endpoint communication is down.<br />

c. The DS1 chel is down between the two DS1 converters in the DS1 converter complex.<br />